Useful Tips When Injection Molding Machine Robots Having a Problem

Useful Tips When Injection Molding Machine Robots Having a Problem


1. The signal of "Robot arms move up" appears abnormally
Tips and solution: Check if the wires are loose,check if sensory switch is working normally.

2. Proximity switch is too far away from sensory metal
Tips and solution: Adjust the distance between the proximity swith and sensory metal.

3. Injection molding machine Robot arm don't move up enough
Tips and solution: Move the robot arms up to theirs up limit by hand.

4. Alarm "AC servo motor abnormal"
Tips and solution: Check the error number, repair according to error numbers.

5. Injection molding machine robot hit something while moving.
Tips and solution: Check if the sensor lights are on,adjust the sensory distance. Check if there are abnormal things on X axes which scratched the robot arm. Turn off the robot, manually move the robot to the middle of X-axes, then turn on the robot.

6. Injection machine don't thimble out occasionly while using injection molding machine robot automatically
Tips and solution: Wire connection not good, Check Aviation connector if plugged tighten, check if wires loosen.

7. Circuit board has a problem or wire connection wrong
Tips and solution: Same solution as number 6.